Microlife Microlife
  • Consumer Products
    • BP A7 Touch BT_half_cuff Blood Pressure
    • Gluco-A_front Blood Glucose
    • NC200_front Thermometers
    • BreastPump_BC200-front Baby Care
    • NEB NANO_half-acc Respiratory Care
    • FH_422 Flexible Heating
    • WS 200 BT_front Weight
    • Software_downloads_allg Software
  • Professional Products
    • WatchBP Office ABI_front_cuff WatchBP Office
    • WatchBP O3 Ambulatory 2G_half_cuff WatchBP O3
    • WatchBP Home A_front_cuff WatchBP Home
    • Cuff-Ankle Cuffs and supplies
    • Software_downloads_WBP Software
  • Technologies
  • Magazine
  • Support
    • BP A2 Basic startseite Product Support
    • Software_downloads_allg Home-Use Software
    • Software_downloads_WBP Professional Software
    • Software Developers Developers
  • Company
    • aboutus About us
    • Events News & Events
    • contact Contact
    • History History
EUROPE
English
Europe
  • EUROPE - English
  • CZECHIA - Čeština
  • DANMARK - Dansk
  • DEUTSCHLAND - Deutsch
  • ESPAÑA - Español
  • FRANCE - Français
  • HRVATSKA - Hrvatski
  • ITALIA - Italiano
  • LATVIJA - Latviešu
  • LIETUVA - Lietuvių
  • MAGYARORSZÁG - Magyar
  • NEDERLAND - Nederlands
  • ÖSTERREICH - Deutsch
  • POLSKA - Polski
  • PORTUGAL - Português
  • SCHWEIZ - Deutsch
  • SLOVENSKO - Slovenčina
  • SUOMI - Suomi
  • UK - English
  • ΕΛΛΆΔΑ - Ελληνικά
  • БЪЛГАРИЯ - Български
  • СРБИЈА - Српски
  • УКРАЇНА - Українська
  • РОССИЯ - Русский
  • БЕЛАРУСЬ - Русский
Asia
  • ASIA PACIFIC - English
  • 中国 - 中文
  • 台灣 - 中文
USA, Latin America
  • AMÉRICA DEL SUR - Español
  • COLOMBIA - Español
  • MÉXICO - Español
  • US - English
Menu
Header Microlife & WatchBP Clinical Studies Flow

Measurement Accuracy of a Stand-Alone Oscillometric Central Blood Pressure Monitor: A Validation Report for Microlife WatchBP Office Central

Home > Professional Products > Validations and clinical studies > Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central. Am J Hypertens, Cheng, 2013
Share

Cheng HM, Sung SH, Shih YT et al. Measurement accuracy of a stand-alone oscillometric central blood pressure monitor: a validation report for Microlife WatchBP Office Central. Am J Hypertens 2013; 26: 42-50

WatchBP Office Central

Background

The superiority of prognostic value of blood pressure (BP) measured at central aorta (CBP) over conventional brachial BP measured by cuff-based BP monitors has reignited the development of new noninvasive techniques for estimating CBP. The present study validated the accuracy of CBP measured by a newly developed stand-alone CBP monitor.

Results

The mean differences of cuff BP with reference to the invasively measured central SBP, PP, and DBP were −2.6 ± 9.0, −8.6 ± 11.2, and 6.1 ± 7.0 mm Hg, respectively, with the former two being obviously underestimated at high CBP and overestimated at low CBP. In contrast, the corresponding differences for the central SBP, PP, and DBP measured by the CBP monitor were −0.6 ± 5.5, −0.4 ± 7.0, and −0.2 ± 6.5 mm Hg, respectively, without obvious systematic bias. The distribution of measurement errors for central SBP, PP, and DBP surpassed the AAMI criteria.

Conclusions

Central SBP, PP, and DBP can be measured accurately by a stand-alone automatic BP monitor.

Click here to download the abstract in pdf format.

Customer support

Contact customer support if you would like our friendly agents to help you resolve your issues.